Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…
Simple Circuit Models for Studying Global Earthing Systems
2007
The paper proposes three simple circuit models for the simulation of the behaviour of a global earthing system during different fault events. The models allow one the evaluation of the maximum earth potential rise at every possible fault location and for every possible fault event. The three considered fault events are: single-line-to-earth fault inside a MV/LV substation, double-earth-fault in a MV line, single-line-to-earth fault inside a HV/MV station. After having illustrated the hypotheses at the basis of the study, the circuit models for the three fault events are presented and a numerical example shows how to use them in order to check the "global safety" of the interconnected earthi…
Comprehensive Modeling and Experimental Testing of Fault Detection and Management of a Nonredundant Fault-Tolerant VSI
2015
This paper presents an investigation and a comprehensive analysis on fault operations in a conventional three-phase voltage source inverter. After an introductory section dealing with power converter reliability and fault analysis issues in power electronics, a generalized switching function accounting for both healthy and faulty conditions and an easy and feasible method to embed fault diagnosis and reconfiguration within the control algorithm are introduced. The proposed system has simple and compact implementation. Experimental results operating both at open- and closed-loop current control, obtained using a test bench realized using a dSPACE system and the fault-tolerant inverter protot…
Investigation of motor current signature and vibration analysis for diagnosing rotor broken bars in double cage induction motors
2012
This paper investigates the detectability of rotor broken bars in double cage induction motors using current signature and vibration analysis techniques. Double cage induction motors are commonly used for applications where successive loaded starts-up are mandatory. Experimental results were performed under healthy and faulty cases, and for different load conditions using each technique. Rotor broken bars fault detection based on sideband current components may fails due to the presence of inter bar currents that reduce the degree of rotor asymmetry, yielding to a decrease of the magnitude of these spectral components. But inter bar currents produce core vibrations in the axial direction, w…
Transient Electrical Behaviour of the TF Superconducting Coils of Divertor Tokamak Test Facility During a Fast Discharge
2022
The paper is focused on the electromagnetic analysis of the Toroidal Field (TF) superconducting coils of the Divertor Tokamak Test facility (DTT) when electrical transients occur in the TF coils system: for example, during the operations of the Fast Discharge Units (FDUs) and considering also, the simultaneous occurrence of a fault condition. During the FDU intervention, a transient voltage excitation lasting few microseconds occurs at the TF coil terminals and it electrically stresses the insulations of TF coils itsef. To investigate the voltage distribution across, inside and between different Double Pancakes (DPs) of each TF coil, a lumped parameters circuital model has been developed an…
Flexible power converters for the fault tolerant operation of Micro-Grids
2010
The progressive penetration level of Distributed Generation (DG) is destined to cause deep changes in the existing distribution networks no longer considered as passive terminations of the whole electrical system. A possible solution is the realization of small networks, namely the Micro-Grids, reproducing in themselves the structure of the main production and distribution of the electrical energy system. In order to gain an adequate reliability level of the microgrids the individuation and the management of the faults with the goal of maintaining the micro-grid operation (fault tolerant operation) is quite important. In the present paper flexible power converters and a companion control al…
A suitable control technique for fault-tolerant converters in Distributed Generation
2011
The penetration of Distributed Generation (DG) in power systems is deeply changing the existing distribution networks which is becoming a very sophisticated and complex systems incorporating both active (generators) and passive systems (distribution systems, converters and loads). The necessary simplification can be obtained dealing with small networks, namely Micro-Grids, reproducing, in a smaller scale, the structure and the problems of large networks including production, transmission and distribution of the electrical energy. In order to achieve an adequate level of reliability, fault-tolerant operations of micro-grids become very important. This result can be achieved only using power …
Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line. A Parametric Analysis
2007
When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through the grounded cable sheaths and discharges into the earth at the transition station, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, the local ground electrode, small and of high resistance, could be inadequate to maintain the ground potential rise within safety limits in case of a fault to ground at the receiving end substation. Based on a circuit model approach, the paper presents a parametric analysis of the fault current distribution between the faulted substation and the transition station, ta…
Experimental validation of a general model for three phase inverters operating in healthy and faulty modes
2012
The paper presents the experimental verification of a general mathematical model of Voltage Source Inverters (VSI) able to simulate fault conditions and which is also useful for the simulation of fault-tolerant systems for different applications. In general, in the past, the problem of faulty inverters modeling has been addressed specifically by considering faults on the different phases as separate cases. Furthermore, traditional models include only the faulty mode and not the healthy mode, so resulting then not able to predict transient phenomena. The model hereafter presented overcomes this drawback. It was formulated by introducing the concept of “healthy leg binary variables”. Such var…
Controlled Fault-Tolerant Power Converters for Power Quality Enhancement
2013
Power quality depends generally on the interaction of electrical power with electrical equipments. If electrical equipments operate correctly and reliably without being damaged or stressed, a suitable level of power quality is assured. On the other hand, if the electrical equipment malfunctions, is unreliable, or is damaged during normal usage, power quality is poor and probably the economical loss could be important like the technical one. In the scenario of the Distributed Generation, power quality issues will be moreover important because an higher dissemination of power conditioning equipment will be requested and this obviously increases the sources of vulnerability of the electrical s…